USA Wind Zone I, II & III Map
Every manufactured home must be designed according to the federal Manufactured Home Construction and Safety Standards at 24 CFR 3280, known as the HUD Code. The HUD Code stipulates, at §3280.305(c)(1) and §3280.305(c)(2), that the home shall be designed and constructed to conform to one of three wind load zones. The appropriate wind zone used in design is dependent on where the home will be initially installed. Homes designed and constructed to a higher Wind Zone can be installed in a lower Wind Zone (a Wind Zone III home can be installed in a Wind Zone I or II location). However, a Wind Zone I home cannot be installed in either a Wind Zone II or III area.

Wind loads (lateral) must be resisted by the home. The home must be capable of transferring these imposed lateral loads to the home’s stabilizing devices without exceeding the allowable stresses and other deflection requirements. Wind Zone I, Wind Zone II and Wind Zone III are identified on the basic wind zone map below. The manufactured home producer designs the home to resist the wind load, which is measured in pounds per square foot. Wind Zone I equates to a 70-mph fastest-mile wind speed. Wind Zone II equates to a 100-mph fastest-mile wind speed. Wind Zone III equates to a 110-mph fastest-mile wind speed.